Lama Pengerjaan, Volume Anestetik Lokal, dan Angka Keberhasilan Blokade Aksilar dengan Panduan Pencitraan Ultrasonografi pada Prosedur Arterio-Venous Shunt

Main Authors: Guntara, Ara, Yadi, Dedi Fitri, Sitanggang, Ruli Herman
Format: Article info application/pdf eJournal
Language: eng
Published: Faculty of Medicine, Universitas Padjadjaran , 2014
Subjects:
Online Access: http://journal.fk.unpad.ac.id/index.php/jap/article/view/329
http://journal.fk.unpad.ac.id/index.php/jap/article/view/329/pdf_31
ctrlnum article-329
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">Lama Pengerjaan, Volume Anestetik Lokal, dan Angka Keberhasilan Blokade Aksilar dengan Panduan Pencitraan Ultrasonografi pada Prosedur Arterio-Venous Shunt</title><creator>Guntara, Ara</creator><creator>Yadi, Dedi Fitri</creator><creator>Sitanggang, Ruli Herman</creator><subject lang="en-US"/><subject lang="en-US">Arterio-venous shunt; blokade aksilar; panduan ultrasonografi</subject><description lang="en-US">Kunci keberhasilan melakukan blokade aksilar adalah mendistribusikan secara optimal anestetik lokal ke sekeliling saraf, hal ini tercapai dengan panduan pencitraan ultrasonografi. Penelitian ini bertujuan menilai lama pengerjaan, volume&#xA0; anestetik lokal, dan angka keberhasilan blokade aksilar dengan panduan pencitraan ultrasonografi. Metode penelitian adalah deskriptif prospektif. Penelitian dilakukan di Rumah Sakit Dr. Hasan Sadikin Bandung pada bulan Maret&#x2013;April tahun 2014 terhadap 40 pasien (21&#x2012;60 tahun), status fisik American Society of Anesthesilogist (ASA) II, menjalani pembedahan dalam blokade aksilar dengan panduan pencitraan ultrasonografi. Fungsi sensorik dan motorik dinilai setiap 5 menit selama 15 menit. Keberhasilan blokade dinilai dari hilangnya fungsi sensorik dan motorik pada saraf medialis, radialis, ulnaris, dan muskulokutaneus. Hasil penelitian didapatkan lama pengerjaan blokade aksilar rata-rata dengan panduan pencitraan ultrasonografi 548 detik (9,1 menit), volume anestetik lokal dibutuhkan 10 mL dan angka keberhasilan blokade aksilar sebesar 97,5%. Penelitian lain lama pengerjaan dengan bantuan alat stimulasi saraf tepi selama 11,2 menit, volume total anestetik lokal dibutuhkan 30&#x2012;40 mL, dan angka keberhasilan 60&#x2012;85%.&#xA0; Simpulan, panduan pencitraan ultrasonografi dapat mempersingkat pengerjaan, mengurangi volume obat anestesi lokal, dan meningkatkan keberhasilan blokade aksilar.Kata kunci: Arterio-venous shunt, blokade aksilar, panduan ultrasonografiProcedure Time, Local Anaesthetic Volume, and Success Rate of Axillary Block with Ultrasound Guidance in Arterio-Venous Shunt ProcedureThe key requirement for successful axillary block is to ensure optimal distribution of local anesthetic around the nerve structure. This goal is most effectively achieved under sonographic visualization. This study aimed to assess block procedure time, minimum volume of local anesthetic required, and success rate of axillary brachial plexus block under ultrasound guidance. This study was conducted between March and April 2014 in Dr. Hasan Sadikin General Hospital, Bandung. This was an observational prospective study involving 40 patients (21&#x2012;60 years old) with American Society of Anesthesiologist (ASA) physical status II who underwent arterio-venous shunt under axillary brachial plexus block. Sensory and motor functions were assessed every five minutes for 15 minutes. A successful block was defined as complete sensoric and motoric loss in median, radial, ulnar, and musculocutaneus nerve distributions by 15 minutes. Results showed average block procedure time of 548 seconds (9.1 min), total volume of local anesthetic of 10 mL, and&#xA0; block success rate of 97.5%. This study concludes that ultrasound guidance can reduce block procedure time and required local anesthetic volume as well as improving the success rate of axillary brachial plexus block. Key words: Arterio-venous shunt, axillary block, ultrasound guidance&#xA0;DOI: 10.15851/jap.v2n3.329</description><publisher lang="en-US">Faculty of Medicine, Universitas Padjadjaran</publisher><contributor lang="en-US"/><date>2014-12-24</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Other:</type><type>Other:</type><type>File:application/pdf</type><identifier>http://journal.fk.unpad.ac.id/index.php/jap/article/view/329</identifier><source lang="en-US">Jurnal Anestesi Perioperatif; Vol 2, No 3 (2014); 181-185</source><source lang="id-ID">Jurnal Anestesi Perioperatif; Vol 2, No 3 (2014); 181-185</source><source>2337-7909</source><language>eng</language><relation>http://journal.fk.unpad.ac.id/index.php/jap/article/view/329/pdf_31</relation><recordID>article-329</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
Other:
File:application/pdf
File
Journal:eJournal
author Guntara, Ara
Yadi, Dedi Fitri
Sitanggang, Ruli Herman
title Lama Pengerjaan, Volume Anestetik Lokal, dan Angka Keberhasilan Blokade Aksilar dengan Panduan Pencitraan Ultrasonografi pada Prosedur Arterio-Venous Shunt
publisher Faculty of Medicine, Universitas Padjadjaran
publishDate 2014
topic Arterio-venous shunt
blokade aksilar
panduan ultrasonografi
url http://journal.fk.unpad.ac.id/index.php/jap/article/view/329
http://journal.fk.unpad.ac.id/index.php/jap/article/view/329/pdf_31
contents Kunci keberhasilan melakukan blokade aksilar adalah mendistribusikan secara optimal anestetik lokal ke sekeliling saraf, hal ini tercapai dengan panduan pencitraan ultrasonografi. Penelitian ini bertujuan menilai lama pengerjaan, volume anestetik lokal, dan angka keberhasilan blokade aksilar dengan panduan pencitraan ultrasonografi. Metode penelitian adalah deskriptif prospektif. Penelitian dilakukan di Rumah Sakit Dr. Hasan Sadikin Bandung pada bulan Maret–April tahun 2014 terhadap 40 pasien (21‒60 tahun), status fisik American Society of Anesthesilogist (ASA) II, menjalani pembedahan dalam blokade aksilar dengan panduan pencitraan ultrasonografi. Fungsi sensorik dan motorik dinilai setiap 5 menit selama 15 menit. Keberhasilan blokade dinilai dari hilangnya fungsi sensorik dan motorik pada saraf medialis, radialis, ulnaris, dan muskulokutaneus. Hasil penelitian didapatkan lama pengerjaan blokade aksilar rata-rata dengan panduan pencitraan ultrasonografi 548 detik (9,1 menit), volume anestetik lokal dibutuhkan 10 mL dan angka keberhasilan blokade aksilar sebesar 97,5%. Penelitian lain lama pengerjaan dengan bantuan alat stimulasi saraf tepi selama 11,2 menit, volume total anestetik lokal dibutuhkan 30‒40 mL, dan angka keberhasilan 60‒85%. Simpulan, panduan pencitraan ultrasonografi dapat mempersingkat pengerjaan, mengurangi volume obat anestesi lokal, dan meningkatkan keberhasilan blokade aksilar.Kata kunci: Arterio-venous shunt, blokade aksilar, panduan ultrasonografiProcedure Time, Local Anaesthetic Volume, and Success Rate of Axillary Block with Ultrasound Guidance in Arterio-Venous Shunt ProcedureThe key requirement for successful axillary block is to ensure optimal distribution of local anesthetic around the nerve structure. This goal is most effectively achieved under sonographic visualization. This study aimed to assess block procedure time, minimum volume of local anesthetic required, and success rate of axillary brachial plexus block under ultrasound guidance. This study was conducted between March and April 2014 in Dr. Hasan Sadikin General Hospital, Bandung. This was an observational prospective study involving 40 patients (21‒60 years old) with American Society of Anesthesiologist (ASA) physical status II who underwent arterio-venous shunt under axillary brachial plexus block. Sensory and motor functions were assessed every five minutes for 15 minutes. A successful block was defined as complete sensoric and motoric loss in median, radial, ulnar, and musculocutaneus nerve distributions by 15 minutes. Results showed average block procedure time of 548 seconds (9.1 min), total volume of local anesthetic of 10 mL, and block success rate of 97.5%. This study concludes that ultrasound guidance can reduce block procedure time and required local anesthetic volume as well as improving the success rate of axillary brachial plexus block. Key words: Arterio-venous shunt, axillary block, ultrasound guidance DOI: 10.15851/jap.v2n3.329
software_str ojs
id IOS9.article-329
institution Universitas Padjadjaran
institution_id 454
institution_type library:university
library
library Fakultas Kedokteran
library_id 4
collection Jurnal Anestesi Perioperatif
repository_id 9
subject_area Anestesi
Perioperatif
Kedokteran
Kesehatan
city BANDUNG
province JAWA BARAT
repoId IOS9
first_indexed 2016-12-22T04:22:33Z
last_indexed 2016-12-22T04:22:33Z
recordtype dc
_version_ 1561212055035314176
score 12.0878725